%0 Thesis %@rightsholder originalauthor yes locatedauthor no %@holdercode {isadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S} %@nexthigherunit 8JMKD3MGPCW/3F2NE4L %@usergroup administrator %@usergroup jefferson %@usergroup sergio %@usergroup sergio@das.inpe.br %@usergroup yolanda.souza@mcti.gov.br %3 paginadeacesso.html %J Development of high sensitivity parametric transducers for the mario schenberg gravitational wave detector %@secondarytype TDI %2 sid.inpe.br/mtc-m18@80/2009/04.07.14.53.45 %A Furtado, Sérgio Ricardo, %P 378 %@dissemination NTRSNASA; BNDEPOSITOLEGAL. %@secondarydate 20090529 %@group AST-SPG-INPE-MCT-BR %K Detector de ondas gravitacionais, Mario Schenberg, transdutor paramétrico, klystron, cavidade ressoante supercondutora, oscilador de micro-ondas, ruído de fase, gravitational wave detector, parametric transducer, klystron, superconducting cavity resonator, phase noise. %@e-mailaddress sergio@das.inpe.br %@documentstage not transferred %I Instituto Nacional de Pesquisas Espaciais (INPE) %@copyholder SID/SCD %@secondarykey INPE-15714-TDI/1472 %9 Tese (Doutorado em Astrofísica) %@area CEA %8 2009-02-19 %X O objetivo principal deste trabalho foi construir um conjunto de transdutores paramétricos do tipo cavidade reentrante com alta sensibilidade e bombeado em 10 GHz para ser utilizado no detector de ondas gravitacionais Mario Schenberg. Estes transdutores monitorarão as vibrações da antena esférica feita de e com de diâmetro na faixa de freqüência de Nióbio com alta concentração de Tântalo e foram testados e utilizados como material para este conjunto de transdutores. As membranas que fecham as cavidades foram fabricadas a partir de lâminas de silício. Diversas cavidades similares às dos transdutores foram construídas e testadas criogenicamente para determinação das freqüências de ressonâncias e dos fatores Q não-carregados em função do acoplamento eletromagnético. Depois de usinadas, as cavidades de receberam um filme de Nióbio, a fim de obter superfícies supercondutoras. Entretanto, devido à baixa espessura dos filmes depositados e/ou não anodização da superfície, para protegê-la de oxidação progressiva, o efeito de supercondutividade não foi verificado. Para as cavidades feitas de Nióbio com alta concentração de Tântalo, obteve-se quando fechadas por tampa do mesmo material. Quando estas cavidades foram fechadas com tampa de Nióbio com concentração de Tântalo inferior ao fator Q não-carregados foi de Desta forma, foi comprovada a influência destas impurezas na obtenção do efeito de supercondutividade. Espera-se obter em 4,2 K, através da utilização de Nióbio com alta pureza e de um tratamento superficial adequado. Também foi construído e testado um novo oscilador de 10GHz com ultra-baixo ruído de fase, utilizando cristal de safira mantido a 77K. Os resultados indicam que a sensibilidade dos novos transdutores será da ordem de em . Os testes experimentais foram realizados nos laboratórios do INPE, da USP, do CETUC-PUC-RJ, do CTA, do LNLS e da University of Western Australia (UWA). ABSTRACT: The main purpose of this work was to build a set of parametric transducers of reentrant cavity type with high sensitivity and pumped at to be used in the gravitational wave detector Mario Schenberg. These transducers will monitor the mechanical vibrations of the -diameter spherical antenna in the frequency range. Niobium with high Tantalum impurities and were tested and used as the material for this set of transducers. The membranes, which close the cavities, were made from silicon blades. Many cavities similar to the parametric transducer cavities were constructed and tested cryogenically to determine their resonant frequencies and non-loaded electrical quality factor related to the electromagnetic coupling. After machined, the cavities received a Niobium film in order to present superconductor performance. However, the effect of superconductivity was not observed due to the small thickness of the deposited films and/or the non-anodization of their internal surfaces, in order to prevent progressive oxidation. For those cavities made of Niobium with high Tantalum impurities, was obtained using a cover made with the same material. When those cavities were closed with a Niobium cover with Tantalum impurities below , the non-loaded electrical quality factor was . It was proved then, the effect of this impurity in the achievement of superconductivity. Using Niobium of high purity and a suitable surface treatment it is expected to obtain at 4.2K. Also a new 10GHz oscillator with an ultra-low phase noise was built and tested using a sapphire crystal at 77K. The results indicate that the sensitivity of the new transducers will be of the order of at . The experimental tests were performed in the laboratories of INPE, USP, CETUC-PUC-RJ, CTA, LNLS and University of Western Australia (UWA). %@project AST-SPG-INPE-MCT-BR %E Vilas Boas, José Williams dos Santos (presidente), %E Aguiar, Odylio Denys de (orientador), %E Jablonski, Francisco José, %E Castro, Joaquim José Barroso de, %E Migliano, Antonio Carlos da Cunha, %E Oliveira Júnior, Nei Fernandes de, %E Tobar, Michael Edmund, %T Desenvolvimento de transdutores paramétricos de alta sensibilidade para o detector de ondas gravitacionais mario schenberg %4 sid.inpe.br/mtc-m18@80/2009/04.07.14.53 %D 2009 %@mirrorrepository sid.inpe.br/mtc-m18@80/2008/03.17.15.17.24 %C São José dos Campos